Design:
Double-acting pneumatic linear cylinder
Diameter of cylinder barrel:
Ø 100 mm
Ø 125 mm
Ø 160 mm
Ø 200 mm
Ø 250 mm
Ø 320 mm
Stroke:
90 mm up to 1030 mm
Supply pressure:
max. 10 bar
Temperature range:
Standard: -20 to +80 °C
High and low temperature design on request
Power range (at 6 bar):
4524 N - 46322 N
Namur Interface:
NAMUR, VDI / VDE 3845
Air supply:
clean and dry compressed air acc. to ISO 8573-1: 2010 min. class 3
Other supply media on request
Valve interface:
based on ISO 5211
Surface:
Body anodized
Cover:
powder-coated
Approval:
Fulfills the requirements of DIN EN15714-3